Myrra

Myrra Encapsulated Transformers

Series 44000   30 VA   EI 66-23


Primary Voltage 230V
Primary
protection
mA
Reference Secondary
voltage
V
Secondary
current
mA
No-load
voltage
V
Ambient
Temperature
°C
Rating
VA
160 44373 6 5000 6.9 T 50 B 30
160 44374 9 3333 10.3 T 50 B 30
160 44375 12 2500 13.8 T 50 B 30
160 44376 15 2000 17.2 T 50 B 30
160 44377 18 1667 20.8 T 50 B 30
160 44378 24 1250 27.7 T 50 B 30
160 44379 2 x 6 2 x 2500 2 x 6.9 T 50 B 30
160 44380 2 x 9 2 x 1667 2 x 10.3 T 50 B 30
160 44381 2 x 12 2 x 1250 2 x 13.8 T 50 B 30
160 44382 2 x 15 2 x 1000 2 x 17.2 T 50 B 30
160 44383 2 x 18 2 x 833 2 x 20.8 T 50 B 30
160 44384* 2 x 24 2 x 625 2 x 27.7 T 50 B 30


Primary Voltage 117V
Primary
protection
mA
Reference Secondary
voltage
V
Secondary
current
mA
No-load
voltage
V
Ambient
Temperature
°C
Rating
VA
315 44385 6 5000 6.9 T 50 B 30
315 44386 9 3333 10.3 T 50 B 30
315 44387 12 2500 13.8 T 50 B 30
315 44388 15 2000 17.2 T 50 B 30
315 44389 18 1667 20.8 T 50 B 30
315 44390 24 1250 27.7 T 50 B 30
315 44391 2 x 6 2 x 2500 2 x 6.9 T 50 B 30
315 44392 2 x 9 2 x 1667 2 x 10.3 T 50 B 30
315 44393 2 x 12 2 x 1250 2 x 13.8 T 50 B 30
315 44394 2 x 15 2 x 1000 2 x 17.2 T 50 B 30
315 44395 2 x 18 2 x 833 2 x 20.8 T 50 B 30
315 44396 2 x 24 2 x 625 2 x 27.7 T 50 B 30

*To be noted: 2 x 24V model is non-approved.
Those transformers meet all requirements of EN 61558-2-4.